Heatex Model H Crossflow Heat Exchanger
Heatex cross flow airflow configuration
Heatex crossflow airflow configuration
Heatex cross flow airflow configuration
Heatex cross flow airflow configuration
Heatex Model H Crossflow Heat Exchanger
Heatex cross flow airflow configuration
Heatex crossflow airflow configuration
Heatex cross flow airflow configuration
Heatex cross flow airflow configuration
Cross Flow

Model H2

Model H2 is a high-performance, low-weight, cross flow plate heat exchanger.

Calculate with Heatex Select
Superior Efficiency
Superior Efficiency

Above 80% sensible efficiency with a single-pass exchanger

Compact
Compact

Lightweight construction with slim frames

Low Pressure Drop
Low Pressure Drop

Due to a optimized plate pattern

Superior Efficiency
Superior Efficiency

Above 80% sensible efficiency with a single-pass exchanger

Compact
Compact

Lightweight construction with slim frames

Low Pressure Drop
Low Pressure Drop

Due to a optimized plate pattern

PRODUCT INFORMATION

Overview

Model H2 is our most efficient cross flow plate heat exchanger. It combines low-weight with high differential pressure resistance and is able to reach typical dry temperature efficiencies above 80%.

The efficiency is improved by its slim profiles and our latest patented plate design, creating high turbulence even at lower velocities while keeping pressure drop low.

A wide range of options including painted framework, epoxy coated plates and closed plate cutting edges will improve corrosion resistance and minimize air leakage even further. Custom made accessories like bypass and dampers are available for all our cross-flow heat exchangers.

Model H2’s performance is certified according to Eurovent, AHRI and TüvSüd. It can easily be configured to comply with Ecodesign 1253/2014 requirements.

All Heatex cross flow plate heat exchangers meet several hygiene requirements.

Technical Data

All available sizes and options listed.

Combined module size
  • 600 – 3000 mm
    (19.69″ – 118.11″)
Plate size
  • 500 / 600 / 700 / 750 / 850 / 1000 / 1200
    (19.69″ / 23.62″ / 27.56″ / 29.53″ / 33.45″ / 39.37″)
Plate material
  • Aluminum
  • Epoxy
End plate
  • Aluzinc >600
  • Aluminum <300
Corner profiles
  • 90° Aluminium
  • 45° Aluminium (not available on H2 1200)
Maximum allowed temperature and sealing
  •  90°C (190° F) – Silicone-free
  • 200°C (390° F) – Silicone
  • 240°C (464° F) – Silicone
Max. leakage (in %)
  • 0.1% of nominal airflow with non-silicone at 400 Pa (1.6″ WC) differential pressure.
  • 1% of nominal airflow for all models with silicone sealant
Max. allowed differential pressure
  • 1800 – 3000 Pa (7.23″ WC – 12″ WC), depending on plate spacing
  • > 3000 Pa (12″ WC) for plate spacing above 4 mm
  • For H2 1200/2400: 1500 – 1700 Pa (6″ WC – 7.23″ WC) for plate spacing 2.0 mm – 3.0 mm (0.08″ –  0.12″)
  • > 3000 Pa (12″ WC) for plate spacing above 4 mm (0.16″)
Documents
Technical Documentation
Conformity
  • Performance - Eurovent

    EN
  • Performance - AHRI

    EN
  • Performance - TüvSüd

    EN
Marketing Material

OPTIONS

We offer a wide range of options to suit various application and performance requirements.

Epoxy plates
Epoxy Coating

For improved corrosion protection in demanding applications such as in coastal environments, all Heatex aluminum heat exchangers are available with epoxy coated plates.

For the highest corrosion protection, we recommend to add both Painted Framework and Closed Plate Cutting Edges.

Heatex model H2 painted framework
Painted Framework

For corrosion protection in wet and humid applications, all Heatex exchangers are available with powder coated framework and sealed joints.

For the highest corrosion protection, we recommend adding both Epoxy Coated Plates and Closed Plate Cutting Edges.

Image coming soon
Closed Plate Cutting Edges

For ultimate corrosion protection, we recommend Closed Plate Cutting Edges which means that lacquer is run along the joints of the plates, covering the cutting edges found on epoxy coated plates. This will also improve the already high tightness of the exchanger and limit leakage to a minimum.

ACCESSORIES

Heatex Damper
Dampers

Suitable for close/open bypass exchanger section in connection with a cross-flow plate heat exchanger.

Heatex Model CS Casing
Model CS

Model CS is a casing for Heatex cross-flow heat exchanger Models H and H2.

Heatex model H2 plate
High Efficiency

Efficiency is improved by a unique and optimized plate design, creating turbulence even at lower velocities.

All units are produced at our global production facilities with our proprietary production equipment according to the same standardized processes, ensuring uniform product quality and favorable lead times worldwide

Heatex plate heat exchangers are tested and approved
Conformity

Heatex air-to-air heat exchangers are designed to comply with all national and local building codes.

We hold several certifications for product and operation quality worldwide, including Eurovent, AHRI, EAC, RLT-Hygiene and ISO 9001.

Our products are field-tested and have proven to deliver a fast ROI.

Computer and men in the office
Technical Expertise

With a global team of sales and technical support, Heatex responds quickly to inquires. We have the technical expertise to customize solutions for your unique needs.

Our products always comply with standards, perform according to (or even exceed) codes and specifications, and always live up to the highest technical standards.

APPLICATIONS

Heatex Model H2 cross-flow heat exchangers are used in a wide area of applications.

CONTACT US

Get in touch! We are always here to help you!

Contact us